A NEW PROCEDURE FOR THE ACCURATE INDOOR MEASUREMENT OF SOLAR-CELL I-V CHARACTERISTICS

dc.contributor.authorGandía, J.J.
dc.contributor.authorCárabe, J.
dc.contributor.authorFabero, F.
dc.contributor.authorJiménez, R.
dc.contributor.authorRivero, J.M.
dc.date.accessioned2026-02-18T13:54:23Z
dc.date.available2026-02-18T13:54:23Z
dc.date.issued2001
dc.description.abstractThe present work describes and validates a method for the adjustment of light intensity in indoor solar-cell I-V tests. The procedure basically consists of the evaluation of the spectral-mismatch parameter as a function of light intensity before measuring. The simulator is set to the irradiance that produces a spectral-mismatch parameter equal to unity (or to some other desired value) and only then is the I-V curve taken. The main advantages are: no need to use very similar reference and test cells, direct extraction of the right whole I-V curve without cell models and ease to measure under different light intensities.es_ES
dc.identifier.citationInternational Journal of Solar Energy, 21(4), 243–256 2001es_ES
dc.identifier.doihttps://doi.org/10.1080/01425910108914373
dc.identifier.urihttps://hdl.handle.net/20.500.14855/5796
dc.language.isoenges_ES
dc.publisherTaylor&Francis on-linees_ES
dc.rights.accessRightsopen accesses_ES
dc.subjectSolar Celles_ES
dc.subjectSpectral mismatches_ES
dc.subjectSolar Simulatores_ES
dc.subjectIndoores_ES
dc.subjectMeasurementes_ES
dc.titleA NEW PROCEDURE FOR THE ACCURATE INDOOR MEASUREMENT OF SOLAR-CELL I-V CHARACTERISTICSes_ES
dc.typejournal articlees_ES