Design, integration and manufacturing of the MEBT and Dplate support frames for IFMIF LIPAc

dc.contributor.authorNomen, Oriol
dc.contributor.authorCastellanos, Jesus
dc.contributor.authorJimenez-Rey, David
dc.contributor.authorPodadera, Ivan
dc.date.accessioned2024-02-12T09:06:38Z
dc.date.available2024-02-12T09:06:38Z
dc.date.issued2017-11-01
dc.description.abstractThe International Fusion Materials Irradiation Facility (IFMIF) [1] aims to provide an accelerator-based, D-Li neutron source to produce high energy neutrons at sufficient intensity and irradiation volume for DEMO materials qualification. As part of the Broader Approach (BA) agreement between Japan and EURATOM, the goal of the IFMIF/EVEDA project is to work on the engineering design of IFMIF and to validate the main technological challenges which, among a wide diversity of hardware includes the LIPAc (Linear IFMIF Prototype Accelerator) [2], a 125 mA continuous wave deuteron accelerator up to 9 MeV mainly designed and manufactured in Europe. The Medium Energy Beam Transport line (MEBT) [3], [4] is in charge of the beam transport at 5 MeV/125 mA and matching beam parameters between two acceleration structures, the RadioFrequency Quadrupole (RFQ) and the Superconducting RF linear accelerator (SRF Linac), while the Diagnostic Plate (DPlate) [5] is a movable module with a set of diagnostics and instrumentations in charge of characterizing the beam in the different accelerator commissioning stages (RFQ commissioning, SRF Linac commissioning) and to provide accelerator operational parameters. Both beamline designs are state of art, being a real engineering (and mechanical) challenge, due to the compactness and alignment requirements from beam dynamics, and the seismic requirements from the accelerator site. An optimized design is critical in order to reduce beam losses and production of radiation at high power beam. The present paper summarizes the mechanical design and analysis of the MEBT and Diagnostic Plate support frames, as well as their manufacturing solutions and mechanical integration with the components installed both in the MEBT and Diagnostic Plate. The mechanical design and integration show the engineering development, adopted to fulfill the strict structural, seismic and alignment requirements.es_ES
dc.description.sponsorshipThis work has been supported by the Spanish Ministry of Economy and Competitiveness in the frame of the BA Agreement Activities.es_ES
dc.identifier.citationFusion Engineering and Designes_ES
dc.identifier.issn0920-3796
dc.identifier.urihttps://hdl.handle.net/20.500.14855/2592
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.relation.ispartofseries123;212-216
dc.rights.accessRightsopen accesses_ES
dc.subjectLIPAces_ES
dc.subjectHigh power acceleratorses_ES
dc.subjectfusion nuetron sourcees_ES
dc.titleDesign, integration and manufacturing of the MEBT and Dplate support frames for IFMIF LIPAces_ES
dc.typejournal articlees_ES

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
S3.7_Design integration and manufacturing of the MEBT and DPlate support frames for IFMIF LIPAc_20160927(1).docx
Size:
1.03 MB
Format:
Microsoft Word XML