(Institución)
 
 

Docu-menta > Energía > Artículos de Energía >

Por favor, use este identificador para citar o enlazar este ítem: http://documenta.ciemat.es/handle/123456789/5796

Título : A NEW PROCEDURE FOR THE ACCURATE INDOOR MEASUREMENT OF SOLAR-CELL I-V CHARACTERISTICS
Autor : Gandía, J.J.
Cárabe, J.
Fabero, F.
Jiménez, R.
Rivero, J.M.
Palabras clave : Solar Cell
Spectral mismatch
Solar Simulator
Indoor
Measurement
Fecha de publicación : 2001
Editorial : Taylor&Francis on-line
Citación : International Journal of Solar Energy, 21(4), 243–256 2001
Resumen : The present work describes and validates a method for the adjustment of light intensity in indoor solar-cell I-V tests. The procedure basically consists of the evaluation of the spectral-mismatch parameter as a function of light intensity before measuring. The simulator is set to the irradiance that produces a spectral-mismatch parameter equal to unity (or to some other desired value) and only then is the I-V curve taken. The main advantages are: no need to use very similar reference and test cells, direct extraction of the right whole I-V curve without cell models and ease to measure under different light intensities.
URI : https://hdl.handle.net/20.500.14855/5796
Aparece en las colecciones: Artículos de Energía

Ficheros en este ítem:

Fichero Descripción Tamaño Formato
1 - 2001 - Gandia - A New Procedure for the Accurate Indoor Measurement of Solar-Cell I-V Characteristics - IJSE 2001.pdf158.97 kBAdobe PDFVisualizar/Abrir
View Statistics

Los ítems de Docu-menta están protegidos por una Licencia Creative Commons, con derechos reservados.

 

Información y consultas: documenta@ciemat.es | Documento legal