Título : Neutron Production Measurement in the 125 MA 5 MeV Deuteron Beam Commissioning of Linear IFMIF Prototype Accelerator (LIPAc) RFQ
Autor : Kondo, K.
Akagi, T.
Bellan, L.
Cara, P.
Carin, Y.
Comunian, M.
Dzitko, H.
Faggoti, E.
Gex, D.
Grspan, F.
Jimenez, D.
Kasugai, A.
Kumagai, K.
Kwon, S.
Masuda, K.
moya, I.
Palmieri, A.
Pisent, A.
Podadera, I.
Rodriguez, A.
Sakamoto, K.
Scantamburlo, F.
Shimosaki, Y.
Shinya, T.
Sugimoto, M.
Palabras clave : LIPAc
Neutron production
High current beam accelerator
Fusion nuetron source
Fecha de publicación : 23-sep-2021
Editorial : IOPScience. Nuclear Fusion
Citación : Keitaro Kondo et al 2021 Nucl. Fusion 61 116002
Citación : 61;11 (116002)
Resumen : The validation of the Linear IFMIF Prototype Accelerator (LIPAc) is being conducted in Rokkasho Fusion Institute of QST, Aomori, Japan. The beam commissioning of the novel LIPAc RFQ has been progressing significantly, and the acceleration of the world highest current deuteron beam of 125 mA to 5 MeV (1 ms, 1 Hz pulsed beam) was achieved for the 1st time in July 2019. This study is devoted to evaluating the amount of beam loss during the high current acceleration phase by measuring the neutron produced by the interaction of the beam with accelerator components so as to verify the accelerator design. The foil activation method and the 3He neutron probes were utilized. It turned out that there was no significant trace of unexpected beam loss at the high energy section of the RFQ and the medium energy beam transport (MEBT) section. The measurement using the 3He neutron probes provided an evidence that the beam loss was well controlled in the RFQ cavity as designed. This study concludes that the LIPAc RFQ as well as MEBT is working well as predicted by the design calculation, and its concept is successful.
URI : http://documenta.ciemat.es/handle/123456789/2605
ISSN : 0029-5515
Aparece en las colecciones: Artículos del Laboratorio Nacional de Fusión

Ficheros en este ítem:

Fichero Descripción Tamaño Formato
S3.4_KONDO_NUCLEAR FUSION.pdf1.14 MBAdobe PDFVisualizar/Abrir
View Statistics

Los ítems de Docu-menta están protegidos por una Licencia Creative Commons, con derechos reservados.

 

Información y consultas: documenta@ciemat.es | Documento legal