Título : | Repairing ribbon bus bar interruptions in photovoltaic modules using non-intrusive interruption location |
Autor : | Rosillo, F.G Nieto-Morone, M.B Benavides Esteva, J Soriano, F Temprano, S González, C Alonso-García, M.C |
Palabras clave : | ribbon bus bar repair photovoltaic modules |
Fecha de publicación : | 2024 |
Editorial : | Renewable Energy |
Resumen : | Ribbon bus bar interruptions in photovoltaic modules represent approximately a 10 % of photovoltaic module
failures. The purpose of the present work is to repair this failures using the simplest, fastest and cheapest
techniques. Twin and single intercell interruptions are defined. The first one, twin intercell interruptions, cut off
electrical current flow between two cells while the second one permits current flow between cells through just
one ribbon bus bar at the cost of module efficiency reduction. We propose non-intrusive methods to find precise
location of single and twin intercell interruptions. A simple technique for intercell interruption repairing is
described. Three modules were repaired, multiplying its power production in two cases by 4, when comparing
with its non-repaired power production. The third module did not produce any electricity before repairing, and
after being repaired produced a power similar to its nominal value. The proposal of repairing can be put into
practice in modestly equipped factories and laboratories, without using expensive and time consuming
techniques. |
URI : | http://documenta.ciemat.es/handle/123456789/2785 |
Aparece en las colecciones: | Artículos de Energía
|
Los ítems de Docu-menta están protegidos por una Licencia Creative Commons, con derechos reservados.
|